Correct Selection of Valve Electric Actuators to Prevent Overload

Valve electric actuator is one of the devices used to operate and connect with valves. Driven by electricity, its movement process can be controlled by the size of stroke, torque or axial thrust. The proper working characteristics and utilization rate of valve electric actuators depend on the type of valve, working specification of the device and the position of the valve on the pipeline or equipment. Therefore, mastering the correct selection of valve electric actuators and preventing the occurrence of overload (working torque higher than control torque) has become a vital part. The correct selection of valve electric actuators should be based on: 1. Operating torque: Operating torque is the main parameter for selecting valve electric actuators. The output torque of the electric actuator should be 1.2 to 1.5 times the maximum operating torque of the valve. 2. Operating thrust: There are two main structures of valve electric actuators, one is not equipped with a thrust disc, which directly outputs torque; the other is equipped with a thrust disc, where the output torque is converted into output thrust through the valve stem nut in the thrust disc. 3. Number of output shaft rotations: The number of rotations of the output shaft of the valve electric actuator is related to the nominal diameter of the valve, valve stem pitch, and number of thread starts, calculated as M=H/ZS (where: M is the total number of rotations the electric actuator should meet; H is the opening height of the valve, mm; S is the pitch of the valve stem drive thread, mm; Z is the number of valve stem thread starts.) 4. Valve stem diameter: For multi-turn rising stem valves, if the maximum valve stem diameter allowed by the electric actuator cannot pass through the valve stem of the matched valve, the electric valve cannot be assembled. Therefore, the inner diameter of the hollow output shaft of the electric actuator must be larger than the outer diameter of the valve stem of the rising stem valve. For part-turn valves and non-rising stem valves among multi-turn valves, although there is no need to consider the passage of the valve stem diameter, the size of the valve stem diameter and keyway should also be fully considered during selection to ensure normal operation after assembly. 5. Output speed: Too fast opening and closing speed of the valve is easy to cause water hammer phenomenon. Therefore, appropriate opening and closing speed should be selected according to different use conditions. 6. Installation and connection mode: The installation methods of electric actuators include vertical installation, horizontal installation and floor installation; the connection modes are: with thrust disc; valve stem passing through (rising stem multi-turn valve); non-rising stem multi-turn; no thrust disc; valve stem not passing through; Part-turn electric actuators are widely used, which are indispensable equipment for realizing valve program control, automatic control and remote control, and are mainly used for closed-circuit valves. However, the special requirement of valve electric actuators cannot be ignored——it must be able to limit torque or axial force. Usually, valve electric actuators adopt torque limiting couplings. When the specification of the electric actuator is determined, its control torque is also determined. When it operates within a pre-determined time, the motor generally will not be overloaded. However, the following conditions can cause overload: 1. The power supply voltage is too low to obtain the required torque, causing the motor to stop running. 2. The torque limiting mechanism is incorrectly adjusted to be larger than the stop torque, resulting in continuous excessive torque and stopping the motor. 3. Intermittent use such as inching operation causes accumulated heat, which exceeds the allowable temperature of the motor. 4. The circuit of the torque limiting mechanism fails for some reason, resulting in excessive torque. 5. The ambient temperature is too high, which relatively reduces the heat capacity of the motor. The above are some causes of overload. The motor overheating phenomenon caused by these causes should be considered in advance, and measures should be taken to prevent overheating. In the past, the methods to protect motors were to use fuses, overcurrent relays, thermal relays, thermostats, etc., but these methods also have their own advantages and disadvantages, and there is no reliable protection method for variable load equipment such as electric actuators. Therefore, a combination of various methods must be adopted. However, since the load conditions of each electric actuator are different, it is difficult to propose a unified method. But summarizing most cases, common points can also be found. The adopted overload protection methods can be summarized into two types: 1. Judge the increase or decrease of the input current of the motor; 2. Judge the heating of the motor itself. No matter which of the above two methods is used, the time margin given by the motor heat capacity should be considered. It is difficult to match the heat capacity characteristics of the motor with a single method. Therefore, a method that can operate reliably according to the cause of overload should be selected——a combined composite method to realize effective overload protection. For the motor of Rotork electric actuator, because a thermostat consistent with the insulation class of the motor is embedded in the winding, when the rated temperature is reached, the motor control circuit will be cut off. The heat capacity of the thermostat itself is small, and its time-limiting characteristic is determined by the heat capacity characteristic of the motor, so this is a reliable method. The basic protection methods for overload are: 1. Adopt thermostat for overload protection of motor continuous operation or inching operation; 2. Adopt thermal relay for motor stall protection; 3. Adopt fuse or overcurrent relay for short circuit accidents. The correct selection of valve electric actuators and overload prevention are closely related, which should be paid attention to.